CHARACTERISTICS & APPLICATIONS

íshín-410R has 12 Cr as nominal composition (wt. %) of weld and is an air-hardening steel. Preheat and post heat treatments are required to achieve welds of adequate ductility for many engineering purposes. The most common application of these electrodes is for welding alloys of similar compositions. They are also used for surfacing of carbon steels to resist corrosion, erosion, or abrasion.

The covering for these electrodes generally contains readily ionizing elements to stabilize the arc for welding with alternating current. Electrode sizes 4.0 mm and smaller may be used in all positions of welding.

Storage and Drying Conditions: Hydrogen can have adverse effects on welds in some steels under certain conditions. One source of this hydrogen is moisture in the electrode coverings. For this reason, the proper storage, treatment, and handling of electrodes are necessary.

Holding Ovens: 125°C–150°C.

Drying Conditions: 250°C–425°C for 1 hour prior to use.

CHEMICAL COMPOSITION OF UNDILUTED WELD

C Cr Ni Mo Nb+Ta Mn Si P S N Cu Others
0.12 11.0-13.5 0.70 0.75 NS 1.00 0.90 0.04 0.03 NS 0.75 NS

Single values are maxima, except where specified otherwise.

ALL-WELD-METAL MECHANICAL PROPERTIES

Heat to 730°C to 760°C, hold for one hour (–0, +15 minutes), furnace cool at a rate not to exceeding 110°C per hour to 315°C and air cool to ambient. Preheat: 200°C minimum and Interpass Temperature: 315°C maximum

Tensile Strength, MPa Yield Strength, At 0.2% Offset, MPa Elongation % Lateral Expansion, mm Charpy V-Notch Impact at NS°C, Joules
520 NS 20 NS NS

Single values are minimal.

ELECTRODE SIZE & WELDING CURRENT (AC and DCEP)

DIAMETER, mm LENGTH, mm Amperes
2.50 350 65-90
3.15, 3.20 350 90-120
4.00 350 120-150
5.00 350 160-200

WARNING: Safety and health information is available from many sources, including, but not limited to Safety and Health Fact Sheets listed in A11.3, ANSI Z49.1 Safety in Welding, Cutting, and Allied Processes published by the American Welding Society, 8669 Doral Blvd., Suite 130, Doral, FL 33166., and applicable federal and state regulations. The Safety and Health Fact Sheets are revised, and additional sheets added periodically.