CHARACTERISTICS & APPLICATIONS

íshín-317LB electrodes deposit alloy content of weld metal which is the same as that deposited by íshín-317R electrodes, except for the carbon content. The 0.04 percent maximum carbon content of weld metal deposited by these electrodes reduces the possibility of intergranular carbide precipitation and thereby increases the resistance to intergranular corrosion without the use of stabilizers such as niobium or titanium. This low-carbon alloy, however, is not as strong at elevated temperatures as the niobium-stabilized alloys or the standard Type 317 weld metal with higher carbon content.

These electrodes are usable with dcep (electrode positive) only. While use with alternating current is sometimes accomplished, they are not intended for use with this type of current. Electrode sizes 4.0 mm and smaller may be used in all positions of welding.

Storage and Drying Conditions: Hydrogen can have adverse effects on welds in some steels under certain conditions. One source of this hydrogen is moisture in the electrode coverings. For this reason, the proper storage, treatment, and handling of electrodes are necessary.

Holding Ovens: 125°C–150°C.

Drying Conditions: 250°C–425°C for 1 hour prior to use.

CHEMICAL COMPOSITION OF UNDILUTED WELD

C Cr Ni Mo Nb+Ta Mn Si P S N Cu Others
0.04 18.0-21.0 12.0-14.0 3.0-4.0 NS 0.5-2.5 1.00 0.04 0.03 NS 0.75 NS

Single values are maxima, except where specified otherwise.

ALL-WELD-METAL MECHANICAL PROPERTIES

Tensile Strength, MPa Yield Strength, At 0.2% Offset, MPa Elongation % Lateral Expansion, mm Charpy V-Notch Impact at NS°C, Joules
520 NS 30 NS NS

Single values are minimal.

ELECTRODE SIZE & WELDING CURRENT (DCEP)

DIAMETER, mm LENGTH, mm Amperes
2.50 350 65-90
3.15, 3.20 350 90-120
4.00 350 120-150
5.00 350 160-200

WARNING: Safety and health information is available from many sources, including, but not limited to Safety and Health Fact Sheets listed in A11.3, ANSI Z49.1 Safety in Welding, Cutting, and Allied Processes published by the American Welding Society, 8669 Doral Blvd., Suite 130, Doral, FL 33166., and applicable federal and state regulations. The Safety and Health Fact Sheets are revised, and additional sheets added periodically.